Control Panels
Designed on "Modular Cubical" system, it
has the facility of extensions or reductions as per
requirements. Each modular cubicle is provided with
swprate base channel to strengthen the cubicle and
also enables easy movement, positioning and facility
of grouting etc. Separate removable gland plates duly
gasketed are provided for cable entry from tom or
bottom, which can be removed and refitted. The design
gives lot of flexibility for easy maintenance and
interchangeability and cuts time loss during maintenance.
Bus-Bars
The Bus-Bar section is specially designed to accommodate
adequate size of Bus Bars to match the current capacity,
and are totally sealed to aviod any human error. The
Bus-Bars are mounted on epoxy moulded type bus-bar
insulators with adequate insulation safety factor.
The Air Gap is totally eliminated by fish plates and
then bolted. adequate gap is maintained between each
phases. The bus bar are insulated with heat shrinkable
sleeves of adequate insulation. All outgoing bus bars
are supported by epoxy insulators of adequate size
to support and sustain the weight of outgoing cables/short
circuit conditions with anti tracking facility. All
incoming bus bars are covered with MS sheet to avoid
any human contact. The Bus Bars material used is aluminium
of Electorlytic grade.
Special Features
›› Door Hinges & Knobs
The Doors are specially designed to provide total
sealing. The door hinges are designed to accomodate
the doors on easily removeable and replaceable pins
with soft rubber gaskets for complete dust proff sealing.
The door knobs are elegantly designed and fitted with
spring loaded lock pin and can be operated by touch
of the finger only.
›› Wiring & Termination
Different type of harnesses are being used for various
starters and meter wiring etc. as per IS-8623 standards.
All components/instruments in the panel are levelled
with proper marking which enable even a layman to
repair the equipments. The standard harnesses enable
easy inter-changeability of feeders. 1.5 sqmm Copper
Flexible wire is used for control wiring, 2.5 sqmm
for CT wiring and minimum 4 sqmm Copper Flexible wire
is used for power wiring. All cable ends are thimbled
and starters are wired upto ready to use termination
point.
›› Bus-Bars Heat Dissipation
The heat generated by the Bus-Bars due to different
working conditions is normalized in the panels through
louvers, cutout, which are provided at the required
places. They allow the heat to escape, which increases
the life of the electrical components. All the louvers
are adequately closed with wire mesh to avoid entry
of insects etc.
›› Accessories
All accessories used are of standard companies and
have been selected after vigorous scrutiny. They meet
all the required quality standards ensuring long life
performance.
›› Testing
Testing facilities available:
1. High Voltage Testing Set.
2. Meggar Test.
3. Conductivity Test.
4. Continuity Test/Multimeter.
5. Phase Sequence Test.
|